DC Inverter air source heat pumps for cooling heating and hot water
This is DC Inverter air source heat pump which can supply all cooling heating and hot water functions. We only use the world famous brands such as Mitsubishi, Hitachi and Panasonic, Monoblock or Split type for option.
Product Info.
Compressor | Mitsubishi |
Capacity | 8KW, 13KW, 15KW, 20KW |
Drive | Hitachi |
Brushless motor | Panasonic |
Circulation pump(for split type) | WILO |
Refrigerant | R410A |
Condenser | “ND” Shell & Coil heat exchanger |
Evaporator | Finned tube heat exchanger with stainless steel 304 of frame |
Fan blades | Metal |
AC contactor & Relay | Schneider |
Electronic expansion valve | Japan Saginomiya or World No.1 Sanhua |
Reversing valve | World No.1 Sanhua |
Controller | LCD, special for DC Inverter |
Package | Wooden case or Carton |
Fasteners | Stainless steel 304 |
Additional Info.
Delivery time | 25 days after order confirmed |
Warranty time | 24 months after shipment |
Payment term | T/T or L/C at sight |
Production capacity | 300 units per month |
Brand | MES or OEM |
Parameters
INVERTER Series (DC Inverter Air source heat pump Cooling Heating & Hot Water) | VT-1609 | |||||
Model | VT8s-D3 | VT13s-D5 | VT15s-D5 | VT20-D8 | ||
Power Supply | V/Hz | 220V~1N/50Hz | 380V~3N/50Hz | |||
Special Power Supply For Option | ||||||
COOLING | Cooling Capacity | kW | 8 | 13 | 15 | 20 |
Cooling Power Input | kW | 2.5 | 4.1 | 4.8 | 6.6 | |
EER | / | 3.2 | 3.2 | 3.1 | 3 | |
Cooling Capacity Range | kW | 3.2?10.5 | 5.5?16.5 | 6?20 | 7?25 | |
Power Input Range | kW | 1.2?3.5 | 1.6?6.1 | 1.8?6.5 | 2.2?9.0 | |
Input Current Range | A | 5.3?15 | 6.4?32 | 7.2?34 | 3.9?18.5 | |
HEATING | Heating Capacity | kW | 9 | 15 | 18 | 24 |
Heating Power Input | kW | 2 | 3.2 | 4 | 5.3 | |
COP | / | 4.5 | 4.6 | 4.5 | 4.5 | |
Heating Capacity Range | kW | 3 ?12 | 5.5?18 | 6.5?22 | 10?28 | |
Power Input Range | kW | 1.0 ?3.8 | 1.6?6.2 | 1.8?6.6 | 2.5?9.2 | |
Input Current Range | A | 4 ?20 | 6.3?33 | 7.2?3.5 | 4.5?22 | |
HOT WATER HEATING | Hot Water Heating Capacity | kW | 12 | 18 | 22 | 30 |
Hot Water Heating Power Input | kW | 2.6 | 4 | 4.9 | 6.6 | |
COP | / | 4.5 | 4.5 | 4.5 | 4.5 | |
Hot Water Heating Capacity Range | kW | 3.3?13.5 | 6?19 | 7?25 | 11?30 | |
Power Input Range | kW | 0.9?3.9 | 1.5?6.3 | 1.7?6.8 | 2.6?9.5 | |
Input Current Range | A | 3.9?21 | 6.1?34 | 7.0?3.6 | 4.6?23 | |
COP | / | 2.5?4.9 | 2.5?5.0 | 2.4?4.9 | 2.6?4.9 | |
Refrigerant | Type | R410A | ||||
Compressor | / | Inverter Rotary | ||||
Heating Setting Temperature | ? | 45?(default) 10?~50?(adjustable) | ||||
Cooling Setting Temperature | ? | 12?(default) 5?~30?(adjustable) | ||||
Hot Water Setting Temperature | ? | 50?(default) 30?-60?(adjustable) | ||||
Fan | Type | / | Axial | |||
Air Flow | m3/h | 3200 | 6300 | 6300 | 7500 | |
Rated Output Power | W | 120 | 240 | 240 | 380 | |
Water Side Heat Exchanger | Type | / | Plate type heat exchanger | |||
Pressure Drop | kPa | =40 | =45 | =45 | =50 | |
Water Connection | DN | 20 | 25 | 25 | 32 | |
Water flow | m3/h | 2.1 | 3.1 | 3.8 | 5.2 | |
Noise | dB(A) | =53 | =55 | =58 | =62 | |
Split type outdoor unit & Monoblock type dimensions(L*W*H) | mm | 973x375x856 | 973x375x1385 | 1163x425x1521 | ||
Split type outdoor unit & Monoblock type wooden Case Package Dimensions(L*W*H) | mm | 1041x443x1024 | 1041x443x1523 | 1231x493x1689 | ||
Split type indoor unit dimensions(L*W*H) | mm | 700x230x560 | ||||
Split type indoor unit wooden Case Package Dimensions(L*W*H) | mm | 756x286x707 | ||||
Net Weight | kg | 120 | 165 | 175 | 215 | |
Gross weight | kg | 130 | 175 | 185 | 232 | |
The parameters on the above table according to the testing condition as below: 1. Cooling testing condition: Dry bulb 35?, wet bulb 24?, water input temp. 12?, water ouput temp. 7?. 2. Heating testing condition: Dry bulb 7?, wet bulb 6?, water input temp. 40?, water ouput temp. 45?. 3. Hot water heating testing condition: Dry bulb 20?, wet bulb 15?, water input temp. 15?, water ouput temp. 55?. 4. The above parameters may have some differences from the final product because of products updating, please refer to final product label, or refer to us for any information. Our company keeps the right to interpret. |
MES, one of the professional manufacturers and suppliers of dc inverter air source heat pumps in China, has been developing and manufacturing heat pumps for over 10 years and become one of the famous such brands. In order to make customers 100% satisfied, we also offer installation service. Now, don't hesitate to buy high quality dc inverter air source heat pumps made in China at competitive price with our factory.
- Residential Water Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)
- Residential Air Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)
- Commercial Air Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)
- Commercial EVI Low Temperature Air Source Heat Pumps 1 Pieces / (Min. Order)
- Residential Water Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)
- Residential Air Source Heat Pumps For Cooling And Heating 1 Pieces / (Min. Order)
- Residential Air Source Heat Pumps Monoblock Type 1 Pieces / (Min. Order)
- Residential Air Source Heat Pumps Split Type 1 Pieces / (Min. Order)